ST-301 SPIDER-Wireline Analyzer

PRODUCTS > Counter-surveillance > ST-301 SPIDER-Wireline Analyzer

ST-301 SPIDER-Wireline Analyzer

Wire lines analyzer is designed to detect and locate eavesdropping devices, galvanically connected to power and low-current wire lines. ST 301 “Spider”
uses passive and active modes of operation to detect enabled, switched o, or faulty
eavesdropping devices.

The Analyzer is designed to detect and localize eavesdropping devices that are galvanically connected to power mains and low-current cables.

In the ST 301, passive and active modes of operation are used to detect enabled, switched off, or faulty eavesdropping devices.

Functionally the Analyzer consists of four components (DEVICES):

1. LOW FREQUENCY AMPLIFIER (LFA)

2. WIRE RECEIVER (WR)

3. NON-LINEAR JUNCTION DETECTOR (NLJD)

4. REFLECTOMETER (REF)

Functionality:

·         Detection and the analysis of signals cable (dynamic and electret) microphones in low-current cables;

·         Activation of electret cable microphones by giving to the cable of bias voltage for their detection;

·         Detection of signals of the eavesdropping devices transferring information on power mains and low-current cables in frequency range of 100 kHz - 180 MHz;

·         Detection of unauthorized galvanic connections to the cables using a NLJD and the REF;

·         Measurement of AC and DC voltage in the low-current cables.

Characteristics:
LOW FREQUENCY AMPLIFIER (LFA)
Frequency range, Hz20 - 25000
Input resistance, kOhm200
Adjustment range of gain, dB0-60
The maximum signal amplitude on an input, V10
Spectral density of noise voltage, nV/Hz6
Bias voltage values, V0, ±5, ±10, ±15, ±20, ±26
Form of representation of a signalOscillogram, Spectrogram
Measurement range on a direct current, V±80
WIRE RECEIVER (WR)
Frequency range, MHz0.1 - 180
Time of scanning of all range, sec0.3 - 1
Minimum level of detected signal in AUTOMATED mode, dBm-60
Dynamic range, dB50
Input resistance, Ohm50
DemodulationAM, FM
Bandwidth of the filter, kHz180
The maximum allowed voltage in the cable, V250 (AC),80 (DC)
Data representation formSpectrogram, Oscillogram, Table.
 NON-LINEAR JUNCTION DETECTOR (NLJD)
Level (amplitude) of the probing signal, V ±14
Frequency of the probing signal, Hz 60
 Separate indication of even and odd harmonics yes
 Minimum detectable level of non-linear distortion, % 0.1
 REFLECTOMETER (REF)
 Range of distances, m 3 - 150
 Error of measurements, m ±0,6
 The ability to work on cables under voltage no
 POWER SUPPLY
The built-in lithium-polymer accumulator, V3.7
Power consumption, W<1
Operating time at the maximum power consumption, hour>3
Charging interval of completely discharged accumulator, hour5
WEIGHT AND DIMENSIONS
Dimensions of the main unit (length, width, height), mm165 x 98 x 40
Mass of the main unit, kg0.47
Packaging dimensions (length, width, height), mm390 x 310 x 170
Mass of the kit in packaging, kg4.4


shared: